Digital Smart Power

Protection Relays

  • SOPR-SS1-60
    Model: SOPR-SS1-60
    Brief:
    SOPR-SS1 Electronic overload relay are designed to monitor single phaseand three-phase motors against overheating and damage caused by Over-load and phaseloss at industrial sites.
  • TH-22(0.1-0.16A)
    Model: 0.1-0.16A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.1-0.16A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-03NH
    Model: FKV-03NH
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Over Voltage : 400V – 480V AC+Off (Adjustable)
    ◉ Under Voltage : 260V – 360V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Neutral-Off Protection
  • TH-22 (0.16-0.25A)
    Model: 0.16-0.25A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.16-0.25A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-03NHF
    Model: FKV-03NHF
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Over Voltage : 400V – 480V AC+Off (Adjustable)
    ◉ Under Voltage : 260V – 360V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Phase Sequence Protection
    ◉ Neutral-Off Protection
  • TH-22(0.25-0.4A)
    Model: 0.25-0.4A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.25-0.4A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-04NH
    Model: FKV-04NH
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Over Voltage : 230V – 300V AC+Off (Adjustable)
    ◉ Under Voltage : 150V – 210V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Neutral-Off Protection
  • TH-22(0.4-0.63A)
    Model: 0.4-0.63A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.4-0.63A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-04NHF
    Model: FKV-04NHF
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Over Voltage : 230V – 300V AC+Off (Adjustable)
    ◉ Under Voltage : 150V – 210V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Phase Sequence Protection
    ◉ Neutral-Off Protection
  • TH-22(0.63-1A)
    Model: 0.63-1A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.63-1A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-53NH
    Model: FKV-53NH
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*220VAC+Neutral)
    ◉ Over Voltage : 130V – 160V AC+Off (Adjustable)
    ◉ Under Voltage : 70V – 100V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Neutral-Off Protection
  • TH-22(1-1.6A)
    Model: 1-1.6A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 1-1.6A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-53NHF
    Model: FKV-53NHF
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*220VAC+Neutral)
    ◉ Over Voltage : 130V – 160V AC+Off (Adjustable)
    ◉ Under Voltage : 70V – 100V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
    ◉ Phase Sequence Protection
    ◉ Neutral-Off Protection
  • TH-22(1.6-2.5A)
    Model: 1.6-2.5A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 1.6-2.5A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-03HF
    Model: FKV-03HF
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*380VAC)
    ◉ Over Voltage : 400V – 480V AC+Off (Adjustable)
    ◉ Under Voltage : 260V – 360V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
  • TH-22(2.5-4A)
    Model: 2.5-4A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 2.5-4A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-53HF
    Model: FKV-53HF
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*220VAC)
    ◉ Over Voltage : 230V – 280V AC+Off (Adjustable)
    ◉ Under Voltage : 150V – 210V AC+Off (Adjustable)
    ◉ Asymmetry : %5 – %50 (Adjustable)
    ◉ Error Waiting Time : 1sec. – 30sec. (Adjustable)
    ◉ Reset Time : 1sec. – 30sec. (Adjustable)
  • TH-22(4-6A)
    Model: 4-6A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 0.25-0.4A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-03ND
    Model: FKV-03ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Neutral-Off Protection
  • TH-22(5-8A)
    Model: 5-8A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 5-8A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-11ND
    Model: FKV-11ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Neutral-Off Protection
    ◉ Without Phase Sequence Protection
  • TH-22(6-9A)
    Model: 6-9A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 6-9A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-12ND
    Model: FKV-12ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Neutral-Off Protection
    ◉ Without Phase Sequence Protection
  • TH-22(7-10A)
    Model: 7-10A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 7-10A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-14ND
    Model: FKV-14ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Neutral-Off Protection
  • TH-22(9-13A)
    Model: 9-13A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 9-13A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-53ND
    Model: FKV-53ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*220VAC+Neutral)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Neutral-Off Protection
  • TH-22(12-18A)
    Model: 12-18A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 12-18A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-61ND
    Model: FKV-61ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Neutral-Off Protection
    ◉ Without Phase Sequence Protection
  • TH-22(16-22A)
    Model: 16-22A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 16-22A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-62ND
    Model: FKV-62ND
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&4W System (3*380VAC+Neutral)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Neutral-Off Protection
    ◉ Without Phase Sequence Protection
  • TH-22(18-26A)
    Model: 18-26A
    Brief:
    TH-22 thermal relay is designed to protect the motor from overheating and damage caused by overload and phase loss.
     
    ◉ Current range: 18-26A
    ◉ Can be used with MC-9, MC-12, MC-18, MC-22
  • FKV-03D
    Model: FKV-03D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*380VAC)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Phase Sequence Protection
  • FKV-11D
    Model: FKV-11D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*380VAC)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Without Phase Sequence Protection
  • FKV-12D
    Model: FKV-12D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*380VAC)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Without Phase Sequence Protection
  • FKV-14D
    Model: FKV-14D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*380VAC)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Phase Sequence Protection
  • FKV-53D
    Model: FKV-53D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as reverse sequence, phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*220VAC)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Phase Sequence Protection
  • FKV-61D
    Model: FKV-61D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*220VAC)
    ◉ Asymmetry : %30 (Fixed)
    ◉ Without Phase Sequence Protection
  • FKV-62D
    Model: FKV-62D
    Brief:
      Phase protection relays are designed to protect three-phase loads from damage caused by faulty voltages such as phase lost, unbalance, etc.
     
    ◉ 3P&3W System (3*220VAC)
    ◉ Asymmetry : %40 (Fixed)
    ◉ Without Phase Sequence Protection
  • FKD-01
    Model:
    Brief:
    3x380VAC. Asym: %20(Fixed). U<270VAC(Fixed). U>:440VAC(Fixed). 
Dongfeng Industrial Zone Yueqing, Zhejiang, 325604, P.R.China
Phone: +86-577-57171337 Fax: +86-577-57171336
COPYRIGHT © 2019 Hannuo Electric ALL RIGHTS RESERVED